Intrinsically Safe Barrier Relays Protect hazardous location circuits and control loads without additional relays or contactors. CIRCUIT PROTECTION AND CONTROL IN ONE COMPACT DEVICE Intrinsically Safe Barrier Relays provide low-cost protection when controlling loads with input devices located in hazardous areas. IS circuits operate at low-energy levels that cannot ignite potentially explosive atmospheres. In the event of a fault condition, the IS barrier prevents excess voltage and current from reaching the hazardous area. ISD SERIES: FOUR CHANNEL DIN-RAIL MOUNTED BARRIER RELAYS ISD Series barrier relays, with a 60 mm wide enclosure, mount on 35mm DIN-rail or can be panel-mounted with screws. These barrier relays provide a safe and reliable method to control up to four loads (motor starters, relays, etc.) with up to four input devices (switches, sensors, etc.) located in a hazardous area. Models are available for time delay or logic selection to be independently applied to each channel. Terminals are removable for easy connection. ISE SERIES: ONE-CHANNEL DIN-RAIL MOUNTED BARRIER RELAYS ISE Series barrier relays, with 17.5 mm wide enclosure, mount on 35mm DIN-rail or can be panel-mounted with screws. These barrier relays provide a safe method to control a single load with a single input device located in a hazardous area. ISP SERIES: ONE-CHANNEL PLUG-IN BARRIER RELAYS ISP Series barrier relays, with an 8-pin plug-in design with socket, can be mounted on 35mm DIN-rail or panel-mounted with two screws. These barrier relays provide a safe method to control a single load with a single input device located in a hazardous area. IS Intrinsically Safe R Time delay or logic selection applied to all channels (ISD and ISE Series only) M Time delay or logic selection independently applied to each channel (ISD Series only) D 60 mm E 17.5 mm P Plug-in Enclosure Number Family Style Control Voltage Function of Channels Standard Modification TYPICAL MODEL CODE ISD, ISE and ISP Series ISD Series ISP Series on Socket ISE Series 1 1 Channel (ISE Series only) 4 4 channels (ISD Series only) V Inverted Operation (ISE Series only) ISD and ISE Series: Both series are approved for use in these Hazardous Locations: Class 1, Div 1 (Zones 0 and 1 Canada), Group A, B, C, D; Class II, Div 1 (Zones 20 and 21 Canada), Group E, F, G; Class III, Div 1 Isolated 5A relay outputs UL913 6th Edition ISD Features Four-channel with independent selection of configuration for each. 60 mm wide enclosure for DIN-rail or panel mounting. Choice of operating modes and time delay ISE Features One-channel 17.5 mm wide enclosure for DIN-rail or panel mounting. Standard or inverse logic ISP Series: One-channel Plug-in enclosure with socket for DIN-rail or panel mounting Approved for use in these Hazardous Locations: Class 1, Div 1, Group A, B, C, D Class II, Div 1, Group E, F, G Class III, Div 1 Isolated 10A relay output UL913 6th Edition 7 U 102-132V AC and 10-125V DC (ISD and ISE Series only) 120A 120V AC (ISP Series Only)