60 MM INTRINSICALLY SAFE BARRIER RELAYS ISD Series The ISD Series of Intrinsically Safe Barrier Relays provide a safe and reliable method to control up to four loads (motor starters, relays, etc.) with up to four input devices (switches, sensors, etc.) located in a hazardous area. The ISD Series relays utilize a compact 60mm wide enclosure that can be both mounted on 35mm DIN rail or panel-mounted with two screws. Terminals for the input devices from the hazardous area are on the bottom of the unit for easy access in the enclosure to incoming field wiring from the hazardous area. Pluggable terminal blocks on both the input and output sides allow for easy initial wiring of the unit as well as replacement without having to remove any wires. ISDUM4 ISDUR4 Approved for use in these Hazardous Locations: Class I, Div 1 (Zones 0 and 1 Canada), Groups A, B, C, D Class II, Div 1 (Zones 20 and 21 Canada), Group E, F, G Class III, Div 1 4-Channel Terminals support 2-wire inputs Isolated 5A relay outputs Pluggable terminals offer easy installation & replacement Universal input voltage of 102- 132V AC & 10-125V DC Compact 60mm wide enclosure for both DIN-rail or panel-mount Standard & inverse logic Instantaneous & delayed response times LED status indicator Each input has two terminals supporting direct connection of 2-wire input devices eliminating the need to mount a separate terminal block. Each output relay is isolated with two wiring terminals providing a true normally-open contact. This allows the output contacts to be used in complex control circuits and allows for each output to switch different voltages with respect to other outputs and the input voltage. A universal input voltage of 102-132V AC & 10-125V DC covers a variety of applications with one device. Operation Each ISD Series product consists of 4 intrinsically safe inputs and four corresponding normally-open relay outputs. With input voltage applied, the V LED will be ON (GREEN) to indicate power is applied. When the input device is closed, the input LED is ON (GREEN). When the output relay is closed, the output LED is ON (ORANGE). The ISD series offers four user-selectable configurations built in. ISDUR4 has a two-position DIP-switch that selects a single configuration for all channels. ISDUM4 has an eight-position DIP-switch that selects a configuration for each channel, independently. Configurations Standard Logic (DIP Switch set to “STD”): When the input device is closed, the corresponding output contact is closed. When the input device is open, the corresponding output contact is open. Inverse Logic (DIP Switch set to “INV”): When the input device is open, the corresponding output contact is closed. When the input device is closed, the corresponding output contact is open. No Time Delay (DIP Switch set to “0 S”): The output contact changes state immediately in response to a change in input device state. UL913 8th Edition 2 Second Delay (DIP Switch set to “2 S”): The output contact will delay 2 seconds before changing state in response to a change in input device state. INPUT VOLTAGE Better. By Design. 800.238.7474 www.macromatic.com [email protected] 4 102-132V AC (50/60Hz) and 10-125V DC 4 SELECTED FOR EACH CHANNEL ISDUM4 DIAGRAM 814 NUMBER OF CHANNELS CONFIGURATION CATALOG NUMBER SELECTED FOR ALL CHANNELS ISDUR4 WIRING intrinsically safe barrier relays | din rail